" We specialize in making RV waste management more sanitary and enviromentally friendly."

PO Box 1333
1591 Shelton Dr
Hollister, Ca. 95024
Toll Free 877-787-8833
831-636-9775

Innovative RV Products

 

  Bookmark Us

VALVE-STER
Manufactured by Phase Four Industries

Product Data Sheet

 

DESCRIPTION

Full flow 3" ABS gate valve adapts to 3" ABS male or female bolt on specific flange fittings. Can be adapted to most pipe sizes with proper fittings and space requirements. Special seals required for sealing between valve and flanges. Gate opens/closes in less than 2 seconds. Indicator light for open or closed position sensing available. DPDT momentary switch is necessary for reversing polarity to motor, can also be controlled with relays and timing circuits. Low pressure (4 psi) applications for transfer of water, air, or vacuum.
Equipped with manual override for emergency opening or closing.

ELECTRICAL

  • Dedicated fused 5 amp circuit
  • Wiring (20 gauge minimum)
  • Momentary DPDT Switch
  • Voltage-12 VDC, reversing polarity through pre-wired switch
  • No load current 1.5 amps, full load current 3.5 amps, locked rotor 5.5 amps.
  • LED OPERATION

    Reed switch activated with magent. Max current - 1/2 AMP.
    For gate positioning - fully open or fully closed.

    PLUMBING

    Valve Installation - good plumbing practices must be followed. Piping should be installed in such a way that the valve is not put in a bind. Access to the valve is necessary for use of manual override and valve replacement when necessary. The valve should have clearance all around. When gluing near valve, care must be taken not to get glue on the gate. All piping must be properly supported. The valve cannot support the piping.

    SEALS

  • The seals are Buna N with graphite additive to enhance lubrication through the life of the seal.
  • Only seals supplied with Valve-Ster will work with the valve - DO NOT use any OTHERS.
  • Proper placement on the flanges and lubrication with Dow Corning 111 are necessary.
  • MECHANICAL OPERATION

    A series of gears allow for a 50:1 gera reduction, developing the necessary torque.

    A manual override is accessible from either side of the valve. It is located within the dome area.

    To activate override, a 1/8” allen wrench is needed. There are directional arrows for

    open/close. Gate is fully opened or closed with a turn and a half on the hex head. The hex head is

    anodized aluminum and can be damaged if improperly used.

    MATERIALS

    ABS plastic, aluminum, stainless steel, acetal, brass, Buna N. anodized aluminum.

    LUBRICATION

    Dow Corning 111

    WARRANTY

    PFI warrants all products to be free from defects in materials and workmanship for a period of 1 year from the date of purchase. This warranty does not include damage to products resulting from accident, misuse, improper installation and unauthorized alterations. PFI's warranty obligation shall be limited to replacement of the product with a new valve (not reconditioned), which will be your exclusive remedy under this warranty. PFI shall not be liable for any special, incidental, indirect or consequential damages whatsoever (including, without limitation, labor or installation charges, damages for loss of business profits, business interruption or any other pecuniary loss) arising out of the use or inability to use the product.

    Tech Support - Toll Free 877-787-8833


    Last Updated Tuesday, March 27 2007 @ 12:23 PM Pacific View Printable Version

    © 2006 All rights reserved Phase Four Industries Created this page in 0.18 seconds                                                                                                                                    Designs by All Merchant Services

    Specializing in :Waste Master, Drain Master, Sewer Master, Pure Power, waster digester, gate valve, dump valve, waste valve, sewer valve, speciality valve, holding tanks treatment, eliminate odors, tank chemicals, Pure Power, Industrial Gate Valve, tank drain valves, waste water control.

    Sanicon, Flojet, digesters, holding tanks, Sewage Pumps amd Sanitation.