NFPA Document Title_ Standard for Recreational Vehicles__ NFPA No. & Year_1192 2005 Edition______
Section/Paragraph __7.5.7 Drain Outlets___________________________________
Comment on Proposal No. (from ROP): ___1192-120 Log # 7_____________
________________________________________________________________________________
NFPA 1192 Standard for Recreational Vehicles
Section 7.5.7 Requested Changes
7.5.7 Drain Outlets.
7.5.7.1 A drain outlet used for the discharge of body waste and liquid waste shall be nominal 3 in. (76.2 mm) pipe size.
7.5.7.2 Except
for listed flexible drain systems, a drain outlet used for the discharge of
liquid waste shall be 1 3 in. (76.2 mm)
minimum pipe size.
in. (38.1 mm)
7.5.7.3 Each
recreational vehicle shall have a main drain outlet(s) that shall terminate
at any point located within 22.5 ft (6.9 m) of the rear in
its storage position, on the left (road) side or at the rear left of the
longitudinal center of the vehicle within 18 in. (457.2 mm) of the outside
wall.
7.5.7.4
When less than 18 in. (457.2 mm) above the ground, the drain
outlet(s) shall be permitted to terminate vertically when it is equipped with a
manual-disconnect-type coupler and a companion elbow hose adapter.
7.5.7.5 A recreational vehicle equipped with only a listed flexible drain system or a side-vent drain system, or designed for transporting livestock, shall be permitted to have its drain outlet located on either side or at the rear, within 18 in. (457.2 mm) of the outside wall. (See also 7.5.7.7.)
7.5.7.6 A recreational vehicle having a mechanical seal toilet with a waste holding tank or a recirculating chemical toilet shall be permitted to have a separate drain outlet installed in accordance with the location requirements specified in 7.5.7.3 through 7.5.7.8.
7.5.7.7 A recreational vehicle with drainage systems limited to a listed flexible drain system and a side-vent drain system shall be permitted to have separate drain outlets for these systems. (See also 7.5.7.5.)
7.5.7.8 Subject to the other requirements in 7.5.7.3 through 7.5.7.7, truck campers shall be permitted to have the main drain(s) located anywhere across the rear of the vehicle.
7.5.7.9 Each
drain outlet shall be equipped with a terminate with a listed
flexible transfer drain hose assembly
(sewer hose) with a minimum of 10 ft. (3.05 m) usable length and a sewer inlet
connection fitting with a shut off valve.. that shall be attached to the
vehicle or drain piping. The listed flexible transfer drain hose
assembly (sewer hose) shall attach to the vehicle piping with a threaded
connection that is accessible for service.
7.5.7.10 Drain
outlets shall be provided with a minimum clearance of 1. The listed flexible transfer drain
hose (sewer hose) and sewer connection fitting shall be provided with an
accessible means of storage.
in. (38.1 mm) on three sides from all parts
of the vehicle. and with clearance directly in front of the outlet to permit
connection of a drain hose or cap
7.5.7.11
Where drain outlets are equipped or arranged for hose
coupling devices, such devices shall be of the manual disconnect type.